[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
About Journal::
Editorial Board::
Articles Archive::
Indexing Databases::
To Authors::
To Reviewers::
Registration::
Submit Your Article::
Policies and Publication Ethics::
Archiving Policy::
Site Facilities::
Contact Us::
::
Google Scholar Metrics

Citation Indices from GS

AllSince 2019
Citations727588
h-index1110
i10-index1512
..
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Registered in

AWT IMAGE

AWT IMAGE

..
:: Volume 9, Issue 3 (6-2022) ::
2022, 9(3): 31-41 Back to browse issues page
Calculation of photoneutron contamination of Varian linac with new target in tissue equivalent phantom using Monte Carlo simulation
Mojtaba Cheraghian , Tayyeb Pourfallah , Amir Abbas Sabouri-Dodaran , Mehrdad Gholami
Department of Biochemistry, Biophysics and Genetics, Medical College, Mazandaran University of Medical Sciences, Sari 48157-33971, Iran , tpourfallah@gmail.com
Abstract:   (608 Views)
Introduction: In this research, a new material (Ti2V0.7Cu97.3) was proposed for the target of medical linear accelerators (linacs) to reduce the production of unwanted photoneutrons in the radiotherapy. So, the fluence, dose equivalent and kerma of the photoneutrons were calculated in a soft tissue phantom.
Materials and Methods: The medical linac was the Varian 2100 C/D 18 MV, which its tungsten target was replaced with a new multi-metal target (Ti2V0.7Cu97.3). Desired quantities were computed in a ICRU soft tissue phantom, using the Monte Carlo code MCNPX (v. 2.6).
Results: The ratio of the maximums of fluence, kerma, and dose equivalent of photoneutrons along the central axis of the ICRU phantom with new target rather than tungsten target were 72 %, 59 % and 61 %, respectively. Average of the Ratio of fluence, kerma, and dose equivalent in inner area (distances less than 5 cm from central axis) at different depths of the phantom with new target rather than tungsten target were 78 %, 70 % and 75 %, respectively. Uncertainties at all points were less than 5 % (except for a few points which were less than 10 %).
Conclusion: This work showed that applying Ti2V0.7Cu97.3 alloy for the target of linac, can reduce the produced photoneutrons up to 38 % by an applicable and inexpensive way.
 
Keywords: MCNPX, Photoneutron contamination, Simulation, Target of linac
Full-Text [PDF 611 kb]   (315 Downloads)    
Type of Study: Research | Subject: Medical physics
Received: 2022/03/30 | Accepted: 2022/05/18 | Published: 2022/06/19
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Cheraghian M, Pourfallah T, Sabouri-Dodaran A A, Gholami M. Calculation of photoneutron contamination of Varian linac with new target in tissue equivalent phantom using Monte Carlo simulation. Journal of Basic Research in Medical Sciences 2022; 9 (3) :31-41
URL: http://jbrms.medilam.ac.ir/article-1-681-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 3 (6-2022) Back to browse issues page
مجله ی تحقیقات پایه در علوم پزشکی Journal of Basic Research in Medical Sciences
Persian site map - English site map - Created in 0.17 seconds with 41 queries by YEKTAWEB 4646